LG Accessory Motor Weak / Obstructed

Mini motorized pet tool or mattress tool has very weak power or stalls easily.

Advertisements

Possible Causes

Hair wrapped around mini brush, Worn mini motor, Blocked air path in accessory, Poor electrical contact at accessory connector

How to Fix / Troubleshooting

Safety first: Remove the battery and detach the accessory.

  • 1. Clean mini brush: Remove the brush (if removable) and clear hair and fibers from the brush and end caps.
  • 2. Inspect connector: Check the electrical contacts on the accessory and main body/wand. Clean gently.
  • 3. Test without load: Run the accessory in the air (no contact with fabric). If it still stalls or is very weak, the motor is likely failing.
  • 4. Replace the accessory: Mini motorized tools are usually replaced as a complete assembly.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Mini Motorized Tool
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements