Logik No Power / Dead Unit

Vacuum will not start at all; no lights or response when pressing the power button.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Completely discharged or failed battery, Faulty charger, Defective main control PCB, Broken power button or trigger

How to Fix / Troubleshooting

Safety first: Ensure the charger is unplugged before handling power components.

  • Check battery charge: Place the battery on the charger and confirm that the charger LED lights. If there is no LED, test another outlet or charger.
  • Try another battery: If possible, test with a known‑good compatible Logik battery to rule out a dead pack.
  • Inspect power button/trigger: Check that the trigger or power button moves freely and is not physically broken.
  • Check for signs of damage: Look for burn marks, cracks, or water ingress. If present, the main control PCB or internal wiring may be damaged and should be replaced by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements