E14
Medion
Brush Head LED / Accessory Power Fault
Cordless vacuum shows E14 and the brush head LEDs flicker or do not light while the brush still spins
Advertisements
Possible Causes
Damaged LED strip in floor nozzle, Loose wiring inside brush head, Poor electrical contact between wand and nozzle, Overcurrent protection tripped for accessory circuit
How to Fix / Troubleshooting
Safety first: Remove the battery and detach the floor nozzle before opening it.
- Check wand contacts: Clean the metal contacts at the end of the wand and on the nozzle with a dry cloth.
- Inspect LED wiring: Open the nozzle housing and trace the wires from the motor connector to the LED strip. Look for broken or pinched wires.
- Test brush function: Reassemble and test. If the brush spins normally but LEDs remain off, the LED strip itself may be burnt out.
- Replace LED strip/nozzle: Replace the LED strip if it is a separate part, or replace the entire floor nozzle assembly if the LEDs are integrated.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
LED Strip in Floor Nozzle
Check Price on Amazon
We may earn a commission from links on this page.