Medion Intermittent Connection in Wiring Harness

Vacuum intermittently cuts out when moving the wand or twisting the handle

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Broken wire inside wand, Loose connector between wand and main body, Damaged flex cable in pivot joint, Cracked solder joint on PCB

How to Fix / Troubleshooting

Safety first: Remove the battery before flexing or opening the wand and handle.

  • Reproduce fault: With the vacuum running (battery installed), gently move the wand and handle to identify positions that cause cut-out. Then remove the battery.
  • Inspect connectors: Check all plug connections between the main body, wand, and nozzle. Reseat them firmly.
  • Open wand (if serviceable): Look for broken or frayed wires, especially near pivot points. Replace the wiring harness if damaged.
  • PCB inspection: If movement near the handle causes cut-out, inspect the PCB for cracked solder joints at the battery or motor connectors and repair or replace the board.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Wiring Harness in Wand
Check Price on Amazon