Possible Causes
Debris lodged around trigger, Broken trigger spring, Worn microswitch under button, Deformed plastic actuator
How to Fix / Troubleshooting
Safety first: Remove the battery before working on the trigger or switch.
- Clean around trigger: Use a soft brush or compressed air to remove dust and debris from around the trigger.
- Inspect mechanism: Open the handle housing to access the trigger and microswitch. Check for broken springs or plastic parts.
- Test microswitch: Press the microswitch directly. If it does not click or register, replace it.
- Replace trigger assembly: If the plastic trigger is cracked or deformed, install a new trigger assembly compatible with your Medion model.