Medion Stuck Power Control / Logic Fault

Vacuum turns on by itself when placed in the dock or when the battery is inserted

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted power button contacts, Stuck trigger mechanism, Faulty main control PCB, Liquid ingress around control area

How to Fix / Troubleshooting

Safety first: Remove the battery immediately if the vacuum powers on unexpectedly.

  • Dry out (if wet): If liquid may have entered the control area, allow the vacuum to dry in a warm, ventilated place for at least 24–48 hours (battery removed).
  • Inspect power button: Open the handle and check for debris or corrosion around the power switch. Clean with isopropyl alcohol and a soft brush.
  • Check switch operation: Test the microswitch with a multimeter (if available). Replace if it is shorted closed.
  • PCB replacement: If the switch is good but the vacuum still auto-starts, replace the main control PCB.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Power Trigger / Microswitch
Check Price on Amazon