Miele
Intermittent Brush Power / Connection Fault
Brush roller starts and stops intermittently while vacuuming
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose electrical contacts between wand and floorhead, Broken wire in wand, Over-sensitive overload protection due to partial jam, Failing brush motor
How to Fix / Troubleshooting
Safety first: Remove the battery before inspecting connections.
- 1. Clean and reseat connections: Detach the Electrobrush and wand, clean the contacts, and reattach firmly.
- 2. Check for cable flex issues: While running the vacuum (battery inserted, keep hands away from moving parts), gently move the wand and connection points. If the brush stops/starts with movement, the wand cable is likely damaged and should be replaced.
- 3. Clear minor jams: Remove the brush roller and clean off any hair or debris that could cause overload trips.
- 4. Replace faulty component: If intermittent operation continues, replace the Electrobrush or wand assembly as indicated by your tests.
Advertisements
Repair Difficulty
Medium
3/5