F7
Miele Power Mode Control / Button Interface Fault

Vacuum cuts out when changing power levels, F7 displayed or power LEDs flash in sequence

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective mode selector switch, Contaminated control buttons, Faulty control PCB in handle, Loose internal connector

How to Fix / Troubleshooting

Safety first: Remove the battery before cleaning or inspecting the controls.

  • 1. Clean around buttons: Use a slightly damp (not wet) microfiber cloth to clean around the power and mode buttons. Dry thoroughly. Do not allow liquid to enter the button gaps.
  • 2. Check for stuck buttons: Press each button several times. Ensure they move freely and return fully. If a button feels stuck, avoid forcing it; internal contamination may require professional cleaning.
  • 3. Power reset: Remove the battery for 5 minutes, then reinsert and test. Sometimes a control PCB glitch can be cleared by a reset.
  • 4. Test in different configurations: Try running the vacuum in handheld mode only (without wand or floorhead). If F7 disappears, the issue may be related to load changes from the Electrobrush.
  • 5. If F7 persists: The handle control PCB or button assembly is likely faulty and should be replaced by a Miele technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Handle Control PCB