Milwaukee
Internal Connection or Safety Interlock Issue
Vacuum shuts off immediately when tilted or carried by the handle.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose internal wiring harness, Poorly seated control PCB, Cracked solder joints at battery contacts, Faulty tilt-sensitive safety switch (if equipped)
How to Fix / Troubleshooting
Safety first: Remove the battery before opening the housing.
- 1. Confirm symptom: With the battery installed, gently move the vacuum while running to reproduce the shutoff, then remove the battery.
- 2. Open housing (if out of warranty): Inspect wiring harnesses from the battery contacts to the control PCB and motor for loose plugs or chafed wires.
- 3. Reseat PCB: Ensure the control PCB is firmly mounted and not flexing when the tool is moved.
- 4. Inspect solder joints: Look for cracked or dull solder at high-current points (battery contacts, MOSFETs). Reflow or replace the PCB if necessary.
- 5. Replace faulty components: If a tilt or safety switch is present and intermittent, replace it or bypass only according to manufacturer-approved procedures.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Wiring Harness / Control PCB