E17
Morphy Richards
Filter Not Fitted / Filter Sensor Error
Cordless vacuum displays E17 and the LED pattern indicates a filter error, suction reduced
Advertisements
Possible Causes
Pre-motor filter missing or not seated correctly, Damaged filter presence magnet or reed switch, Wrong type of filter installed, Debris blocking filter sensor area
How to Fix / Troubleshooting
Safety first: Remove the battery before removing or refitting filters.
- Check filter installation: Remove the pre-motor filter and reinstall it carefully, ensuring it is fully seated and the cover is locked.
- Use correct filter: Confirm you are using the correct Morphy Richards filter type for your model. Some sensors rely on specific shapes or magnets in the filter frame.
- Clean sensor area: If your model uses a magnetic or optical filter sensor, gently clean around the filter housing to remove dust that may block detection.
- Test without bin (if allowed): Some models allow a brief test without the bin to see if the error changes. Follow the manual; do not run the motor for more than a few seconds without proper filtration.
- Sensor failure: If E17 persists with a correct, properly seated filter, the filter sensor (reed switch or optical sensor) on the main body may be faulty and require PCB or sensor replacement.