E3
Morphy Richards Airflow Restriction / Blocked Air Path

Cordless vacuum displays E3 and suction is very weak or pulsing

Advertisements

Possible Causes

Clogged cyclone assembly, Blocked wand or extension tube, Severely clogged pre-motor filter, Obstruction at bin inlet flap

How to Fix / Troubleshooting

Safety first: Switch off the vacuum and remove the battery before disassembling any parts.

  • Empty the dust bin: Remove the bin and empty it completely. Tap gently to dislodge compacted dust from the cyclone shroud.
  • Clean cyclone shroud: Use a soft brush to clean the perforated metal or plastic shroud inside the bin. Do not wash the cyclone unless the manual explicitly allows it.
  • Check wand and tools: Detach the wand and all tools. Look through each section for blockages and push them out with a flexible, non-sharp rod if needed.
  • Clean filters: Remove the pre-motor filter (usually foam or fabric) and tap off dust outdoors. If the manual allows, rinse under lukewarm water until clear, then air-dry for at least 24 hours before refitting. Never refit damp filters.
  • Inspect bin inlet flap: Ensure the rubber or plastic flap at the bin inlet moves freely and is not stuck closed by debris.
  • Reassemble and test: Once all parts are clean and dry, reassemble and test. If E3 persists with clear airflow, the pressure sensor or control PCB may be faulty and require professional service.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Pre-Motor Filter
Check Price on Amazon

We may earn a commission from links on this page.