E13
Nilfisk
Tilt/Orientation Sensor or Internal Connection Fault
Vacuum cuts out when tilted or rotated; intermittent power loss during use
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose battery connection, Broken wire in handle harness, Faulty tilt/orientation sensor on PCB, Cracked solder joints on power terminals
How to Fix / Troubleshooting
Safety: Remove the battery before inspection.
- Check battery fit: Ensure the battery locks firmly into place. If it feels loose, inspect the latch and housing for wear.
- Wiggle test: With the battery installed and the unit running, gently move the handle and body. If power cuts out with movement, an internal connection is likely loose.
- Inspect external joints: Check the wand and nozzle electrical joints for play or visible damage.
- Do not open the PCB housing yourself: Intermittent faults often require re-soldering or harness replacement. Contact a Nilfisk service center for internal inspection.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Handle Wiring Harness
Check Price on Amazon