E17
Nilfisk
Battery Temperature Protection During Charging
LED display shows a thermometer over a battery; charging stops prematurely
Advertisements
Possible Causes
Battery pack too hot or too cold, Faulty temperature sensor inside battery, Charger thermal protection triggered, Blocked ventilation around charger
How to Fix / Troubleshooting
Safety: Place the charger and battery on a hard, non-flammable surface away from heat sources.
- Normalize temperature: If the battery was just used heavily, let it cool for 30–60 minutes before charging. If stored in a cold area, allow it to warm to room temperature.
- Ensure ventilation: Do not cover the charger or battery while charging. Keep away from direct sunlight or radiators.
- Retry charging: Once at room temperature, reconnect the charger and monitor the LED status.
- If temperature error persists: The internal temperature sensor or BMS may be faulty. Replace the battery pack.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Nilfisk Lithium-Ion Battery Pack
Check Price on Amazon