Nilfisk
Nozzle LED Circuit Failure
LED lights on the floor nozzle do not illuminate, but brushroll and suction work
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Burned-out LED strip, Broken wire in nozzle, Faulty LED driver on nozzle PCB, Loose connector inside nozzle
How to Fix / Troubleshooting
Safety: Remove the battery and detach the nozzle.
- Check external wiring: Inspect the nozzle neck for visible cable damage.
- Open nozzle (if user-serviceable): Remove screws and carefully open the nozzle housing to inspect the LED strip connection.
- Reseat connectors: Ensure the LED strip plug is firmly connected to the nozzle PCB.
- Replace LED strip/nozzle: If the strip is visibly damaged or still does not light, replace the LED strip or entire nozzle assembly.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Floor Nozzle LED Strip
Check Price on Amazon
We may earn a commission from links on this page.