Numatic
General Suction Loss
Cordless vacuum has very weak suction but motor sounds normal
Advertisements
Possible Causes
Clogged filters, Air leak at hose or seals, Blocked hose or wand, Dust bin not sealing correctly
How to Fix / Troubleshooting
Safety first: Remove the battery and empty the dust bin.
- Inspect for blockages: Detach hose, wand, and tools. Look through each for obstructions and clear them.
- Clean filters: Remove pre-motor and exhaust filters. Tap out dust and wash if allowed. Let them dry completely before refitting.
- Check seals: Inspect the rubber seals around the bin, hose inlet, and filter housing. Replace any that are cracked or flattened.
- Test without accessories: Run the vacuum body alone to compare suction. If strong at the body but weak at the floor head, the issue is in the hose, wand, or head.
Advertisements
Repair Difficulty
Easy
2/5