Progress Worn or Misaligned Trigger Switch

Vacuum trigger must be held very hard or at a specific angle to keep the unit running

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Mechanical wear of trigger, Failing microswitch, Misaligned trigger linkage, Cracked handle housing

How to Fix / Troubleshooting

Safety: Remove the battery before opening the handle.

  • Inspect trigger movement: Check for cracks or excessive play in the trigger.
  • Open handle: Access the trigger mechanism and microswitch. Ensure the trigger properly actuates the switch.
  • Replace switch or handle: If the microswitch is worn or the trigger is cracked, replace the switch or the entire handle assembly with a genuine Progress part.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Trigger Switch
Check Price on Amazon