Progress
Worn or Misaligned Trigger Switch
Vacuum trigger must be held very hard or at a specific angle to keep the unit running
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Mechanical wear of trigger, Failing microswitch, Misaligned trigger linkage, Cracked handle housing
How to Fix / Troubleshooting
Safety: Remove the battery before opening the handle.
- Inspect trigger movement: Check for cracks or excessive play in the trigger.
- Open handle: Access the trigger mechanism and microswitch. Ensure the trigger properly actuates the switch.
- Replace switch or handle: If the microswitch is worn or the trigger is cracked, replace the switch or the entire handle assembly with a genuine Progress part.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Trigger Switch
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements