Possible Causes

Wand not fully inserted, Cracked wand tube, Dust bin not latched, Gasket missing between bin and motor housing

How to Fix / Troubleshooting

Safety first: Turn off and remove the battery before inspecting the air path.

  • Check connections: Ensure the wand is fully inserted into both the handle and floor head until it clicks.
  • Inspect wand: Look for visible cracks or holes along the wand. Replace the wand if damaged.
  • Verify dust bin latch: Make sure the dust bin is fully closed and latched. Open and close it firmly.
  • Check seals: Inspect the rubber seals where the bin meets the motor housing. If a seal is missing or flattened, replace the dust bin or seal kit.