Possible Causes

Blown accessory power fuse on PCB, Broken power pins in extension tube, Damaged wiring harness to accessory port, Faulty main control PCB output stage

How to Fix / Troubleshooting

Safety first: Remove the battery before inspecting electrical contacts.

  • Inspect the electrical contacts on the main body, extension tube, and powered accessories for bent or recessed pins.
  • Test with different powered accessories (floor head, mini motorized brush). If none receive power, the issue is in the main body or tube.
  • Check continuity of the extension tube wiring if you have a multimeter; replace the extension tube with electrical contacts if open circuit is found.
  • If the tube is good and E14 persists, the main control PCB likely has a failed accessory power driver and should be replaced.