E6
Roidmi
Brush Motor Communication / Hall Sensor Error
Vacuum beeps and stops; display/app shows E6, often when using the motorized floor head or mini power brush.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Damaged cable between floor head and main body, Faulty brush motor hall sensor, Loose connector in brush head, Water ingress into brush head electronics
How to Fix / Troubleshooting
Safety first: Turn off the vacuum and remove the battery.
- Disconnect the extension tube and floor head from the main body.
- Inspect the electrical contacts at both ends of the extension tube and on the floor head for bent pins, corrosion, or debris. Clean gently with a dry cloth.
- Reconnect firmly until you hear a click. Ensure there is no play in the connection.
- If the model has a mini motorized brush, test with that attachment. If E6 only occurs with one head, that head is likely faulty.
- If E6 persists with a specific head, replace the complete motorized floor brush assembly or mini motorized brush as applicable.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Motorized Floor Brush Assembly