Roidmi Battery or Motor Overheating

Vacuum handle or battery area becomes excessively hot to the touch during normal use.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked airflow causing motor strain, Failing battery cells generating heat, Continuous use on MAX power, Dirty filters increasing load

How to Fix / Troubleshooting

Safety first: Stop using the vacuum and remove the battery. Allow it to cool completely.

  • Perform a full cleaning of bin, cyclone, and filters to restore airflow.
  • Use lower power modes for routine cleaning; reserve MAX for short bursts.
  • If the battery itself is hot while the motor area is only warm, the battery may be failing; replace the battery pack.
  • If the motor housing is extremely hot and there is a burning smell, the main motor assembly may be failing and should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Battery Pack
Check Price on Amazon