Roidmi Intermittent Electrical Connection

Vacuum turns on only when the handle is held at a certain angle or when the tube is twisted.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose battery contacts, Broken wire in extension tube, Cracked solder joint on PCB, Worn connector between body and tube

How to Fix / Troubleshooting

Safety first: Remove the battery before inspecting connectors.

  • Inspect the battery contacts and housing for wear or looseness. Gently bend spring contacts (if present) to improve contact, without deforming them excessively.
  • Check the connection between the main body and extension tube; ensure it clicks firmly into place.
  • Test the vacuum with and without the extension tube. If the problem only occurs with the tube, replace the extension tube with wiring.
  • If the issue persists regardless of tube position, the fault may be on the main control PCB or internal wiring, requiring professional repair.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Extension Tube
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements