Rowenta Filtration Inefficiency / Leaking Filter Seal

Cordless vacuum leaves fine dust on hard floors; visible dust cloud when starting or stopping.

Advertisements

Possible Causes

Damaged or missing HEPA/post‑motor filter, Filter not seated correctly, Cracked filter housing, Using non‑genuine filter with poor fit

How to Fix / Troubleshooting

Safety first: Turn OFF and remove the battery before handling filters.

  • Check filter presence: Open the filter compartment and ensure the HEPA/post‑motor filter is installed.
  • Inspect filter condition: Look for tears, holes, or deformation in the filter media. Replace if damaged.
  • Verify seating: Ensure the filter is fully inserted and the cover is latched properly so air cannot bypass the filter.
  • Use genuine filters: Replace with genuine Rowenta filters designed for your model to ensure proper sealing and filtration performance.
  • Clean surrounding area: Wipe dust from the filter housing and seals before installing the new filter.
Advertisements

Repair Difficulty

Very Easy 1/5

Required Part

HEPA / Post-Motor Filter
Check Price on Amazon

We may earn a commission from links on this page.