Rowenta
Filtration Inefficiency / Leaking Filter Seal
Cordless vacuum leaves fine dust on hard floors; visible dust cloud when starting or stopping.
Advertisements
Possible Causes
Damaged or missing HEPA/post‑motor filter, Filter not seated correctly, Cracked filter housing, Using non‑genuine filter with poor fit
How to Fix / Troubleshooting
Safety first: Turn OFF and remove the battery before handling filters.
- Check filter presence: Open the filter compartment and ensure the HEPA/post‑motor filter is installed.
- Inspect filter condition: Look for tears, holes, or deformation in the filter media. Replace if damaged.
- Verify seating: Ensure the filter is fully inserted and the cover is latched properly so air cannot bypass the filter.
- Use genuine filters: Replace with genuine Rowenta filters designed for your model to ensure proper sealing and filtration performance.
- Clean surrounding area: Wipe dust from the filter housing and seals before installing the new filter.
Advertisements
Repair Difficulty
Very Easy
1/5
Required Part
HEPA / Post-Motor Filter
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements