Brush Head Connection / Recognition Fault
Cordless vacuum shows F3; LED on the brush head may flash and the brush roll does not turn.
Advertisements
Possible Causes
Dirty or bent electrical contacts between wand and brush head, Broken wiring in wand, Incompatible or non‑Rowenta brush head, Faulty brush head PCB
How to Fix / Troubleshooting
Safety first: Remove the battery and detach the brush head before cleaning contacts.
- Clean contacts: Inspect the metal pins and pads on both the wand and brush head. Wipe with a dry cloth. If there is light oxidation, gently rub with a pencil eraser, then wipe clean.
- Check for bent pins: Straighten slightly bent pins carefully with small pliers. Do not force them.
- Test without wand: If your model allows, connect the brush head directly to the handheld unit to bypass the wand. If it works, the wand wiring is likely faulty.
- Try another head: If you have another compatible Rowenta motorized head, test it. If F3 disappears, the original head is defective.
- Replace faulty component: Replace the wand or brush head assembly if continuity is lost or the PCB is faulty.