C07
Samsung High-Power Mode Overcurrent / Motor Protection

Vacuum shows C07 and will not run at high power; may run briefly on low.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Partially blocked cyclone assembly, Severely clogged HEPA filter, Failing motor drawing excess current, Faulty power mode control on PCB

How to Fix / Troubleshooting

Safety first: Remove the battery before cleaning or inspection.

  • Deep clean cyclone and filters: Disassemble the cyclone assembly per the manual. Tap out dust and rinse washable parts with water if allowed. Clean or replace the HEPA filter if heavily soiled.
  • Check for hidden clogs: Look inside the cyclone inlets and outlet ports for compacted dust.
  • Test on low and medium: After reassembly, test the vacuum on lower modes. If it works fine but fails only on max, the motor may be near its limit.
  • Try with a fully charged battery: Low battery voltage can trigger overcurrent protection in high mode. Fully charge and retest.
  • If C07 persists on high with clean airflow and full battery: The motor or main PCB current sensing circuit may be defective. Professional service is recommended.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Suction Motor Assembly