C12
Samsung
Accessory Motor Overload / Short
Vacuum shows C12 and shuts off when using motorized accessories (mini brush, pet tool).
Advertisements
Possible Causes
Jammed mini motorized brush, Shorted accessory motor, Damaged accessory PCB, Excessive hair wrapped around accessory roller
How to Fix / Troubleshooting
Safety first: Remove the battery and detach the accessory before working on it.
- Clean the accessory: Remove the roller from the mini motorized tool. Cut away hair and debris from the roller and end caps.
- Check roller movement: Ensure the roller spins freely by hand. If stiff or seized, replace the roller assembly.
- Test without accessory: Run the vacuum with no powered accessory attached. If it runs normally, the issue is isolated to the accessory.
- Try another powered tool: If another motorized tool works fine, replace the faulty accessory.
- If C12 appears with all powered tools: The accessory power output on the main PCB may be faulty. Professional diagnosis is required.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Mini Motorized Tool
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements