Vacuum shows E7 and the LED lights on the floor head flash; brush will not operate.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Turn OFF the vacuum and remove the battery before inspecting electrical contacts.
- 1. Remove and reattach wand: Detach the wand from the main body and floor head. Reattach firmly until you hear a click at both ends.
- 2. Clean contacts: Inspect the metal contacts at the wand ends and on the floor head and main body. Wipe gently with a dry, lint‑free cloth. Do not use liquids.
- 3. Visual inspection: Look for bent pins, burn marks, or melted plastic around the connectors. If any are found, the affected part should be replaced.
- 4. Test with another attachment: If you have a smaller powered tool (e.g., TCL mini motorized brush), connect it directly to the main body. If it works, the issue is likely in the floor head or wand.
Next step: Persistent E7 indicates a communication or power fault to the floor head. Replace the extension wand or motorized floor head assembly as indicated by your tests, or have a technician check continuity and replace the internal harness or PCB.