E7
Xiaomi Accessory Communication / Identification Error

Vacuum displays E7 or a specific LED pattern when the motorized brush or mini power head is attached, but works without it

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Damaged electrical contacts on wand or accessory, Broken wiring in extension tube, Faulty accessory PCB, Non-original or incompatible accessory

How to Fix / Troubleshooting

Safety first: Remove the battery before inspecting electrical contacts.

  • Inspect contacts: Look at the metal contacts on the main body, extension wand, and motorized head. Clean gently with a dry cloth. Ensure contacts are not bent or recessed.
  • Test without wand: Attach the motorized head directly to the main body (if design allows). If it works, the extension tube wiring is likely damaged.
  • Try another accessory: If another powered accessory (e.g., mini motorized brush) works fine, the original head is likely faulty and should be replaced.
  • Check for third-party parts: Some non-Xiaomi heads may not be recognized correctly. Use original Xiaomi accessories designed for your model.
  • Replace faulty component: If cleaning contacts does not help and only one accessory triggers the error, replace that accessory. If all powered accessories fail, the wand or main body contact board may need replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Extension Wand with Electrical Contacts
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements