Xiaomi Intermittent Electrical Connection

Vacuum intermittently cuts out when moving the wand or twisting the handle

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Broken wire inside extension wand, Loose connector between body and wand, Worn contacts on motorized head, Cracked solder joint on PCB

How to Fix / Troubleshooting

Safety first: Remove the battery before inspecting connectors.

  • Recreate fault: With the vacuum assembled, gently move the wand and head while running (briefly) to confirm movement causes cut-out. Then remove the battery.
  • Inspect connectors: Check the mechanical and electrical joints between main body, wand, and head. Clean contacts and ensure they click firmly into place.
  • Test without wand: Attach the head directly to the main body (if possible). If the issue disappears, the wand wiring is likely damaged and should be replaced.
  • Replace faulty section: If movement at a specific joint always causes cut-out, replace that component (wand, head, or main body).
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Extension Wand with Electrical Contacts
Check Price on Amazon

We may earn a commission from links on this page.