Zanussi Imbalanced Brush Roll or Fan

Vacuum produces excessive vibration in the hand or floor head during use.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Brush roll clogged on one side, Warped or bent brush bar, Damaged motor fan blades, Debris stuck in fan

How to Fix / Troubleshooting

Safety first: Remove the battery and detach the floor head.

  • Clean brush roll thoroughly: Remove all hair and debris from the entire length of the brush, including end caps.
  • Check for straightness: Roll the brush on a flat surface; if it wobbles, it may be bent and should be replaced.
  • Test without floor head: Run the vacuum briefly without the nozzle. If vibration disappears, the issue is in the head; if it remains, the motor fan may be damaged.

Persistent vibration from the main body indicates a likely motor fan imbalance, requiring motor assembly replacement by a technician.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Motorised brush roll assembly
Check Price on Amazon

We may earn a commission from links on this page.