Balay Detergent Dispenser / Spray Coverage Issue

Detergent tablet remains partially or completely undissolved in the dispenser at the end of the cycle.

Advertisements

Possible Causes

Blocked spray arm not reaching dispenser, Dispenser door blocked by dishes, Low water temperature, Weak circulation pump

How to Fix / Troubleshooting

Safety first: Turn off and unplug the dishwasher before checking spray arms.

  • Check loading near dispenser: Ensure tall plates or pans are not placed directly in front of the dispenser door. Leave space for it to open fully.
  • Clean spray arms: Remove and clean spray arms to ensure strong jets reach the dispenser area.
  • Run hot program: Use a hotter program to ensure the tablet dissolves completely.
  • Try powder or gel: As a test, use powder detergent in the dispenser. If powder also remains, suspect a circulation or temperature issue.
  • Replace dispenser if faulty: If the door does not open reliably during the cycle, the dispenser assembly may need replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Detergent Dispenser
Check Price on Amazon