F6
Bauknecht
Water Intake / Flow Meter Fault
Dishwasher shows F6 and does not fill with water; you may hear a short attempt to start then stop.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective flow meter in water inlet system, Blocked water softener or inlet channel, Faulty inlet valve, Wiring issue between flow meter and control board
How to Fix / Troubleshooting
Safety first: Unplug the dishwasher and close the water tap.
- Verify supply and hose: Confirm water tap is open and inlet hose is not kinked. Clean the inlet filter as described for F1.
- Check for internal leaks: Remove the left side panel (on many Bauknecht models) to access the water matrix / distribution chamber and flow meter. Look for heavy limescale or blockages in the channels.
- Clean water matrix: If accessible, flush the water matrix and softener inlet with warm water and a descaling solution to remove deposits that may prevent the flow meter from turning.
- Inspect wiring: Ensure the small harness from the flow meter to the main control board is firmly connected and not damaged.
- Component replacement: If water flows physically but the machine still reports F6, the flow meter or inlet valve assembly may be defective and should be replaced.