E18
Bertazzoni
Insufficient Water Level / Short Fill
Dishwasher displays E18; unit fills only partially or stops with low water level in the tub.
Advertisements
Possible Causes
Partially clogged inlet valve filter, Low household water pressure, Kinked inlet hose, Faulty flow meter undercounting water
How to Fix / Troubleshooting
Safety first: Disconnect power and turn off water.
- 1. Clean inlet filter: Shut off water, disconnect the inlet hose at the valve, and remove and clean the small mesh filter.
- 2. Check hose routing: Ensure the inlet hose is not kinked or pinched behind the dishwasher.
- 3. Verify water pressure: Confirm that other fixtures have good flow. If pressure is low, consult a plumber.
- 4. Flow meter: If the physical water level looks normal but E18 appears, the flow meter may be miscounting and should be cleaned or replaced.
After cleaning and correcting supply issues, run a test cycle to confirm normal filling.