E19
Bertazzoni Regeneration Valve / Softener Control Error

Dishwasher shows E19; regeneration or softener cycle does not complete correctly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective regeneration valve coil, Blocked softener channels, Wiring fault to regeneration valve, Control board output failure

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing side panels.

  • 1. Access regeneration valve: Remove the side panel to locate the small valve connected to the water softener system.
  • 2. Inspect and test: Check the valve coil for continuity with a multimeter. Inspect connectors and wiring.
  • 3. Clean softener channels: If accessible, flush the softener channels with warm water to remove salt buildup.
  • 4. Replace valve: If the coil is open or the valve is stuck, replace it with a compatible Bertazzoni regeneration valve.

If E19 persists, the main control board may not be driving the valve correctly and should be evaluated by a technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Regeneration Valve
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements