E25
Bosch
Drain Pump Impeller Blocked or Cover Missing
Dishwasher displays E25 and will not drain; often accompanied by grinding noises.
Advertisements
Possible Causes
Foreign object in drain pump, Missing or loose pump cover, Damaged impeller, Blocked sump outlet
How to Fix / Troubleshooting
Safety first: Disconnect power before reaching into the sump.
- Remove filters: Take out the filter assembly to expose the sump area.
- Access pump cover: Locate the small plastic cover over the drain pump inlet (often with a tab). Twist or pull it out according to the manual.
- Clear obstructions: Reach into the pump cavity and remove any glass, bones, or debris. Rotate the impeller gently to ensure it moves freely.
- Check pump cover: Ensure the cover is not cracked and that its seal is intact. Reinstall it securely; a missing cover can cause E25.
- Test drain: Reinstall filters and run a drain or rinse cycle to confirm proper operation.
Advertisements
Repair Difficulty
Easy
2/5