E25
Bosch Drain Pump Impeller Blocked or Cover Missing

Dishwasher displays E25 and will not drain; often accompanied by grinding noises.

Advertisements

Possible Causes

Foreign object in drain pump, Missing or loose pump cover, Damaged impeller, Blocked sump outlet

How to Fix / Troubleshooting

Safety first: Disconnect power before reaching into the sump.

  • Remove filters: Take out the filter assembly to expose the sump area.
  • Access pump cover: Locate the small plastic cover over the drain pump inlet (often with a tab). Twist or pull it out according to the manual.
  • Clear obstructions: Reach into the pump cavity and remove any glass, bones, or debris. Rotate the impeller gently to ensure it moves freely.
  • Check pump cover: Ensure the cover is not cracked and that its seal is intact. Reinstall it securely; a missing cover can cause E25.
  • Test drain: Reinstall filters and run a drain or rinse cycle to confirm proper operation.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Drain Pump
Check Price on Amazon

We may earn a commission from links on this page.