E16
Brandt Inlet Valve Stuck Open / Water Inlet Error

Dishwasher shows E16 and may continuously fill or drain, sometimes with water entering even when off.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck or leaking water inlet valve, Faulty aqua-stop hose, Control board triac shorted, Debris preventing valve closure

How to Fix / Troubleshooting

Safety first: Immediately close the water tap and disconnect power to prevent flooding.

  • 1. Confirm continuous fill: With the dishwasher switched off, open the door and check if water continues to enter. If so, the inlet valve or aqua-stop is stuck open.
  • 2. Inspect inlet valve: Remove the toe-kick and side panel to access the inlet valve or aqua-stop assembly. Check for debris in the valve filter and housing. Clean if minor debris is present.
  • 3. Replace faulty valve: If the valve continues to leak when de-energized, replace the water inlet valve / aqua-stop hose.
  • 4. Check control board: If the valve is mechanically sound but remains energized, the control board triac may be shorted, continuously powering the valve. In this case, the main PCB must be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Water Inlet Valve / Aqua-Stop Hose
Check Price on Amazon