Champion Worn Membrane Keypad / Switch Panel

Control panel buttons are hard to press or do not respond consistently, but no error code is shown.

Advertisements

Possible Causes

Aged or cracked membrane keypad, Moisture ingress behind panel, Loose keypad ribbon cable, Physical damage from cleaning chemicals

How to Fix / Troubleshooting

Safety first: Disconnect power before removing the control panel.

Restoring keypad function:

  • Inspect keypad surface: Look for cracks, bubbles, or delamination on the Champion keypad. Replace if damaged.
  • Dry moisture: Remove the panel and gently dry any moisture behind the keypad. Ensure the area is sealed to prevent future ingress.
  • Reseat ribbon cable: Disconnect and reconnect the keypad ribbon cable to the control board, ensuring a firm connection.
  • Avoid harsh cleaners: Use only mild cleaners on the control panel to prevent further damage.

When to call a technician: If a new keypad does not resolve the issue, the control board may also be damaged and require replacement.