E18
Champion
Low Water Pressure / Flow Fault
Machine reports low incoming water pressure; E18 displayed and cycles may be inhibited.
Advertisements
Possible Causes
Insufficient building water pressure, Clogged external supply filter, Partially closed shutoff valve, Faulty internal flow switch or pressure sensor
How to Fix / Troubleshooting
Safety first: Turn off power before opening any internal water connections.
Steps to diagnose:
- Measure supply pressure: Use a pressure gauge at the Champion dishwasher inlet to confirm pressure meets the minimum specified on the data plate.
- Check shutoff valves: Ensure all upstream valves are fully open and not partially closed.
- Clean external filters: If a line strainer or filter is installed, shut off water, remove the screen, and clean debris and scale.
- Inspect internal flow switch / sensor: Locate the flow switch or pressure sensor inside the machine. Check for obstructions and verify electrical continuity or signal output.
- Consult plumbing: If building pressure is inadequate, a booster pump or plumbing changes may be required.
When to call a technician: If internal sensors or control logic are at fault, a Champion technician should perform further diagnostics.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Champion Water Flow Switch
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements