Classeq Inconsistent Chemical Dosing

Classeq dishwasher chemical dosing seems inconsistent; sometimes too much, sometimes too little detergent.

Advertisements

Possible Causes

Worn peristaltic pump tube, Air ingress in suction line, Incorrect dosing time settings, Blocked injector or non‑return valve

How to Fix / Troubleshooting

Safety first: Wear appropriate PPE when handling chemicals. Isolate power before servicing pumps.

  • Inspect pump tube: On peristaltic detergent and rinse aid pumps, check the flexible tube for flattening, cracks, or hardness. Replace if worn.
  • Eliminate air leaks: Ensure suction tubes are fully submerged and connections are tight. Replace brittle tubing.
  • Clean injectors: Remove and clean chemical injectors and non‑return valves to ensure free flow.
  • Recalibrate dosing: Using Classeq's procedure, set and verify dosing times to achieve the correct concentration.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Detergent Dosing Pump Tube
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements