E16
Classeq Rinse Aid Dosing Pump Fault

Classeq dishwasher shows E16; rinse aid not being dispensed correctly or rinse aid alarm active.

Advertisements

Possible Causes

Empty rinse aid container, Blocked rinse aid suction filter, Failed rinse aid pump, Air lock in dosing line

How to Fix / Troubleshooting

Safety first: Disconnect power and wear gloves when handling rinse aid chemicals.

  • Verify rinse aid level: Ensure the rinse aid container is filled and the suction tube is correctly positioned.
  • Clean suction filter: Remove the small filter at the end of the suction tube and rinse under warm water to remove residue.
  • Prime the pump: On models with a priming function, run the rinse aid pump manually until you see liquid moving through the clear dosing tube and into the machine.
  • Inspect pump operation: Locate the rinse aid dosing pump. Check for leaks, cracked tubing, or a worn pump head. Replace if the pump does not run or fails to move liquid.
  • Check electrical supply: Confirm the pump receives power during the rinse phase (qualified personnel only). If not, suspect a control PCB output fault.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Rinse Aid Dosing Pump
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements