E17
Classeq Low Water Pressure / Supply Fault

E17 displayed; machine indicates low incoming water pressure or insufficient flow.

Advertisements

Possible Causes

Closed or partially closed stopcock, Clogged inlet filter, Undersized or kinked supply hose, Building water pressure too low

How to Fix / Troubleshooting

Safety first: Turn off power before moving the machine or disconnecting hoses.

  • Check stopcock and isolation valves: Ensure all valves feeding the Classeq dishwasher are fully open.
  • Inspect inlet hose: Look for kinks, crushing, or sharp bends in the water inlet hose. Straighten or replace as needed.
  • Clean inlet filter: Turn off water, disconnect the hose at the machine, and remove the mesh filter. Clean thoroughly and refit.
  • Measure water pressure: If possible, measure static and dynamic pressure at the supply. If below Classeq's minimum specification, consult a plumber to improve supply (e.g., larger pipework or booster pump).
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Water Inlet Hose
Check Price on Amazon

We may earn a commission from links on this page.