E1
CMA Dishmachines Fill Timeout / Low Water Level Fault

Machine will not fill; display shows E1 shortly after start, wash pump does not run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Clogged inlet water strainer, Defective fill solenoid valve, Low incoming water pressure, Faulty water level float switch

How to Fix / Troubleshooting

Safety first: Turn off the dishmachine power at the breaker and close the incoming water supply valve before servicing. Allow the unit to cool.

Step-by-step checks:

  • Verify water supply: Confirm the building’s hot water supply to the machine is ON and at the required pressure and temperature per CMA specifications.
  • Clean inlet strainer: Locate the incoming water line strainer (usually at the connection to the machine). Shut off water, remove the strainer, and clean out debris under running water. Reinstall and open the valve.
  • Inspect fill solenoid valve: With power OFF, access the fill valve assembly. Check for clogged inlet screen and mineral buildup. Clean or replace the valve if the coil is open or the valve is stuck closed.
  • Check float and float switch: Open the tank and verify the mechanical float moves freely up and down. Remove any debris or scale around the float guide. Test the float switch with a multimeter for proper continuity when raised and lowered.
  • Test operation: Restore power and water, then start a cycle. If E1 persists after cleaning and verifying water supply, the fill valve or float switch likely needs replacement.

When to call a technician: If you are not comfortable working with live electrical components or the machine still will not fill after these steps, contact a qualified CMA service technician.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Fill Solenoid Valve