Rinse pump or rinse solenoid fault; display shows E8 and no final rinse water sprays.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Turn off power and close the rinse water supply. Hot water under pressure can cause burns.
Step-by-step checks:
- Inspect rinse nozzles: Remove and clean the final rinse nozzles. Mineral scale or debris can block spray and mimic a pump/valve failure.
- Check rinse line strainer: Locate and clean the rinse line strainer or filter. Flush with water to remove sediment.
- Test rinse solenoid valve: With power OFF, check the coil for continuity. Inspect for scale buildup or a stuck plunger. Replace the valve if the coil is open or the valve is mechanically stuck.
- Rinse pump (if installed): Verify the pump spins freely and is not leaking. Test motor windings with a meter. Replace the pump if seized or electrically open.
When to call a technician: If the control board is not energizing the rinse circuit or if plumbing modifications are needed, contact a CMA service technician.
Repair Difficulty
Required Part