CMA Dishmachines Rinse Aid Injection Failure

Rinse aid is not being dispensed; dishes are wet and have poor sheeting.

Advertisements

Possible Causes

Empty rinse aid container, Air in rinse aid line, Failed rinse aid pump, Blocked rinse aid injection fitting

How to Fix / Troubleshooting

Safety first: Wear gloves when handling rinse aid chemicals.

Step-by-step checks:

  • Check supply: Confirm the rinse aid container is not empty and the pickup tube is submerged.
  • Prime the line: Use the pump’s prime function to remove air from the line until rinse aid flows steadily.
  • Inspect tubing and injector: Look for kinks or blockages in the tubing and at the injection point into the rinse line. Clean or replace as needed.
  • Test pump operation: Energize the pump in test mode. Replace the pump if it fails to run when powered.

When to call a technician: If the control does not energize the pump or the injection point is inaccessible, contact a CMA technician.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Rinse Aid Pump
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements