CMA Dishmachines
Rinse Aid Injection Failure
Rinse aid is not being dispensed; dishes are wet and have poor sheeting.
Advertisements
Possible Causes
Empty rinse aid container, Air in rinse aid line, Failed rinse aid pump, Blocked rinse aid injection fitting
How to Fix / Troubleshooting
Safety first: Wear gloves when handling rinse aid chemicals.
Step-by-step checks:
- Check supply: Confirm the rinse aid container is not empty and the pickup tube is submerged.
- Prime the line: Use the pump’s prime function to remove air from the line until rinse aid flows steadily.
- Inspect tubing and injector: Look for kinks or blockages in the tubing and at the injection point into the rinse line. Clean or replace as needed.
- Test pump operation: Energize the pump in test mode. Replace the pump if it fails to run when powered.
When to call a technician: If the control does not energize the pump or the injection point is inaccessible, contact a CMA technician.