CMA Dishmachines Rinse Arm Flow Failure

Rinse arms do not spray or rotate; final rinse appears weak or absent.

Advertisements

Possible Causes

Clogged rinse nozzles, Blocked rinse line strainer, Low rinse pressure, Defective rinse solenoid or pump

How to Fix / Troubleshooting

Safety first: Turn off power and close the rinse water supply before removing rinse arms.

Step-by-step checks:

  • Clean rinse nozzles: Remove rinse arms and clean each nozzle opening with a small brush or pick.
  • Check strainer: Clean the rinse line strainer to restore flow.
  • Verify pressure: Confirm that building and regulated rinse pressure meet CMA specifications.
  • Test solenoid/pump: Energize the rinse solenoid or pump in test mode. Replace if not operating correctly.

When to call a technician: If rinse flow remains inadequate after cleaning and basic checks, a technician should evaluate the booster and internal plumbing.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Rinse Arm Assembly
Check Price on Amazon

We may earn a commission from links on this page.