Comenda
Door Alignment / Latch Binding
Door is difficult to close or requires excessive force.
Advertisements
Possible Causes
Misaligned cabinet or machine leveling, Bent door latch, Obstructed gasket, Swollen or misfitted panels
How to Fix / Troubleshooting
Safety first: Disconnect power before mechanical adjustments.
- Level and align: Adjust leveling feet so the machine is square and stable.
- Inspect latch: Check the door hook and striker for bending or misalignment. Adjust or replace as needed.
- Check gasket: Ensure the gasket is seated correctly and not folded or pinched.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Door Latch Assembly
Check Price on Amazon
We may earn a commission from links on this page.