E12
Comenda Rinse Aid Dosing System Fault

Rinse aid dosing error; streaks or spots on glasses and E12 displayed on some models.

Advertisements

Possible Causes

Empty rinse aid container, Blocked rinse aid suction filter, Faulty rinse aid dosing pump, Air leak in rinse aid tubing

How to Fix / Troubleshooting

Safety first: Wear gloves when handling rinse aid chemicals.

  • Check rinse aid level: Confirm the external or built-in rinse aid reservoir is filled.
  • Inspect suction filter: Remove and clean the small filter at the end of the rinse aid suction tube.
  • Check tubing: Look for cracks, loose connections, or air bubbles in the transparent tubing. Replace damaged sections and ensure tight connections.
  • Prime the system: Use the machine’s priming function or run several cycles to purge air from the line.
  • Test pump: During final rinse, verify that the rinse aid pump runs. If it does not, and voltage is present, replace the pump.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Rinse Aid Dosing Pump
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements