E18
Comenda Boiler Overtemperature / Safety Trip

Boiler overtemperature; machine locks out heating and displays E18.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed boiler thermostat, Stuck boiler contactor, Scale buildup reducing heat transfer, Faulty control board

How to Fix / Troubleshooting

Safety first: Disconnect power and allow boiler to cool completely. Boiler components can be under pressure and very hot.

  • Reset safety thermostat: Press the manual reset on the boiler safety thermostat if present. If it trips again, investigate cause.
  • Descale boiler: Heavy scale can cause localized overheating. Follow Comenda’s descaling procedure or have a technician descale the boiler.
  • Check contactor: Ensure the boiler contactor opens when heating is not requested. Replace if welded closed.
  • Verify control settings: Confirm that boiler temperature setpoint is within recommended range.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Boiler Safety Thermostat
Check Price on Amazon