E5
Comenda
Booster / Rinse Boiler Heating Failure
Rinse boiler does not reach temperature; machine may not allow final rinse and displays E5.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed boiler heating element, Faulty boiler thermostat or NTC probe, Tripped high-limit safety thermostat, Defective boiler contactor or relay
How to Fix / Troubleshooting
Safety first: Isolate power and allow the machine to cool. The boiler area can be extremely hot and under pressure.
- Check high-limit thermostat: Locate the manual reset safety thermostat on the boiler body. Press the reset button if present. If it trips repeatedly, investigate overheating causes.
- Inspect wiring and contactor: Open the electrical panel and check the boiler contactor/relay and wiring for signs of burning or loose connections. Tighten terminals as needed.
- Test boiler element: With power off and wires removed, measure resistance across the boiler heater terminals. An open circuit indicates a failed element that must be replaced.
- Check boiler NTC/thermostat: Inspect the temperature probe for scale buildup. Clean gently and test resistance against Comenda specifications. Replace if readings are out of range or intermittent.
- Verify supply voltage: Ensure the correct three-phase or single-phase supply is present at the boiler contactor when heating is requested.
Due to high power and pressure, boiler repairs are best handled by a qualified technician.