Comenda
Boiler Underheating Without Alarm
Rinse water is cold; dishes are not sanitized properly though no specific error code is shown.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Partially failed boiler element (multi-section), Incorrect temperature setpoint, Faulty temperature sensor drifting, Undersized electrical supply
How to Fix / Troubleshooting
Safety first: Disconnect power before testing heating components.
- Measure rinse temperature: Use a thermometer at the rinse outlet to confirm actual temperature.
- Check setpoints: Verify boiler temperature settings in the control menu.
- Test elements: Measure resistance of each boiler element section; replace any that are open or significantly higher than spec.
- Sensor calibration: Replace the boiler NTC if readings are inaccurate.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Boiler Heating Element
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements