E11
Constructa Temperature Sensor Signal Out of Range

Dishwasher shows E11 and may not heat or may stop mid-cycle.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted NTC sensor,Corroded NTC connector,Moisture ingress in sensor wiring,Control board input fault

How to Fix / Troubleshooting

Safety first: Disconnect from mains before any electrical checks.

  • 1. Inspect NTC connector: Access the NTC at the sump or heater housing. Disconnect and check for corrosion or moisture. Dry and clean the contacts if needed.
  • 2. Check cable harness: Follow the harness from the NTC to the control board. Look for crushed, cut, or chewed wires (especially if rodents are possible).
  • 3. Reseat connectors: At the control board (usually in the door), disconnect and reconnect the NTC plug to ensure a good contact.

When to call a technician: If E11 remains, the NTC or control board likely needs replacement and should be tested with proper diagnostic tools.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.